Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Int J Comput Assist Radiol Surg ; 19(4): 713-721, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38233597

RESUMEN

PURPOSE: Navigation guidance is a key requirement for a multitude of lung interventions using video bronchoscopy. State-of-the-art solutions focus on lung biopsies using electromagnetic tracking and intraoperative image registration w.r.t. preoperative CT scans for guidance. The requirement of patient-specific CT scans hampers the utilization of navigation guidance for other applications such as intensive care units. METHODS: This paper addresses bronchoscope tracking by solely incorporating video data. In contrast to state-of-the-art approaches, we entirely omit the use of electromagnetic tracking and patient-specific CT scans to avoid changes in clinical workflows and additional hardware requirements in intensive care units. Guidance is enabled by means of topological bronchoscope localization w.r.t. a generic airway model. Particularly, we take maximally advantage of anatomical constraints of airway trees being sequentially traversed. This is realized by incorporating sequences of CNN-based airway likelihoods into a hidden Markov model. RESULTS: Our approach is evaluated based on multiple experiments inside a lung phantom model. With the consideration of temporal context and use of anatomical knowledge for regularization, we are able to improve the accuracy up to to 0.98 compared to 0.81 (weighted F1: 0.98 compared to 0.81) for a classification based on individual frames. CONCLUSION: We combine CNN-based single image classification of airway segments with anatomical constraints and temporal HMM-based inference for the first time. Our approach shows first promising results in vision-based guidance for bronchoscopy interventions in the absence of electromagnetic tracking and patient-specific CT scans.


Asunto(s)
Algoritmos , Broncoscopía , Humanos , Broncoscopía/métodos , Imagenología Tridimensional/métodos , Broncoscopios , Tomografía Computarizada por Rayos X/métodos , Fenómenos Electromagnéticos
2.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37713626

RESUMEN

AIMS: Electro-anatomical voltage, conduction velocity (CV) mapping, and late gadolinium enhancement (LGE) magnetic resonance imaging (MRI) have been correlated with atrial cardiomyopathy (ACM). However, the comparability between these modalities remains unclear. This study aims to (i) compare pathological substrate extent and location between current modalities, (ii) establish spatial histograms in a cohort, (iii) develop a new estimated optimized image intensity threshold (EOIIT) for LGE-MRI identifying patients with ACM, (iv) predict rhythm outcome after pulmonary vein isolation (PVI) for persistent atrial fibrillation (AF). METHODS AND RESULTS: Thirty-six ablation-naive persistent AF patients underwent LGE-MRI and high-definition electro-anatomical mapping in sinus rhythm. Late gadolinium enhancement areas were classified using the UTAH, image intensity ratio (IIR >1.20), and new EOIIT method for comparison to low-voltage substrate (LVS) and slow conduction areas <0.2 m/s. Receiver operating characteristic analysis was used to determine LGE thresholds optimally matching LVS. Atrial cardiomyopathy was defined as LVS extent ≥5% of the left atrium (LA) surface at <0.5 mV. The degree and distribution of detected pathological substrate (percentage of individual LA surface are) varied significantly (P < 0.001) across the mapping modalities: 10% (interquartile range 0-14%) of the LA displayed LVS <0.5 mV vs. 7% (0-12%) slow conduction areas <0.2 m/s vs. 15% (8-23%) LGE with the UTAH method vs. 13% (2-23%) using IIR >1.20, with most discrepancies on the posterior LA. Optimized image intensity thresholds and each patient's mean blood pool intensity correlated linearly (R2 = 0.89, P < 0.001). Concordance between LGE-MRI-based and LVS-based ACM diagnosis improved with the novel EOIIT applied at the anterior LA [83% sensitivity, 79% specificity, area under the curve (AUC): 0.89] in comparison to the UTAH method (67% sensitivity, 75% specificity, AUC: 0.81) and IIR >1.20 (75% sensitivity, 62% specificity, AUC: 0.67). CONCLUSION: Discordances in detected pathological substrate exist between LVS, CV, and LGE-MRI in the LA, irrespective of the LGE detection method. The new EOIIT method improves concordance of LGE-MRI-based ACM diagnosis with LVS in ablation-naive AF patients but discrepancy remains particularly on the posterior wall. All methods may enable the prediction of rhythm outcomes after PVI in patients with persistent AF.


Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Medios de Contraste , Gadolinio , Estudios de Cohortes , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Atrios Cardíacos/patología , Imagen por Resonancia Magnética/métodos , Cardiomiopatías/etiología , Ablación por Catéter/efectos adversos
3.
Comput Med Imaging Graph ; 108: 102265, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37392493

RESUMEN

Digital twins of patients' hearts are a promising tool to assess arrhythmia vulnerability and to personalize therapy. However, the process of building personalized computational models can be challenging and requires a high level of human interaction. We propose a patient-specific Augmented Atria generation pipeline (AugmentA) as a highly automated framework which, starting from clinical geometrical data, provides ready-to-use atrial personalized computational models. AugmentA identifies and labels atrial orifices using only one reference point per atrium. If the user chooses to fit a statistical shape model to the input geometry, it is first rigidly aligned with the given mean shape before a non-rigid fitting procedure is applied. AugmentA automatically generates the fiber orientation and finds local conduction velocities by minimizing the error between the simulated and clinical local activation time (LAT) map. The pipeline was tested on a cohort of 29 patients on both segmented magnetic resonance images (MRI) and electroanatomical maps of the left atrium. Moreover, the pipeline was applied to a bi-atrial volumetric mesh derived from MRI. The pipeline robustly integrated fiber orientation and anatomical region annotations in 38.4 ± 5.7 s. In conclusion, AugmentA offers an automated and comprehensive pipeline delivering atrial digital twins from clinical data in procedural time.


Asunto(s)
Fibrilación Atrial , Humanos , Atrios Cardíacos/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos
4.
J Cardiovasc Electrophysiol ; 34(8): 1613-1621, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37365931

RESUMEN

INTRODUCTION: Improved sinus rhythm (SR) maintenance rates have been achieved in patients with persistent atrial fibrillation (AF) undergoing pulmonary vein isolation plus additional ablation of low voltage substrate (LVS) during SR. However, voltage mapping during SR may be hindered in persistent and long-persistent AF patients by immediate AF recurrence after electrical cardioversion. We assess correlations between LVS extent and location during SR and AF, aiming to identify regional voltage thresholds for rhythm-independent delineation/detection of LVS areas. (1) Identification of voltage dissimilarities between mapping in SR and AF. (2) Identification of regional voltage thresholds that improve cross-rhythm substrate detection. (3) Comparison of LVS between SR and native versus induced AF. METHODS: Forty-one ablation-naive persistent AF patients underwent high-definition (1 mm electrodes; >1200 left atrial (LA) mapping sites per rhythm) voltage mapping in SR and AF. Global and regional voltage thresholds in AF were identified which best match LVS < 0.5 mV and <1.0 mV in SR. Additionally, the correlation between SR-LVS with induced versus native AF-LVS was assessed. RESULTS: Substantial voltage differences (median: 0.52, interquartile range: 0.33-0.69, maximum: 1.19 mV) with a predominance of the posterior/inferior LA wall exist between the rhythms. An AF threshold of 0.34 mV for the entire left atrium provides an accuracy, sensitivity and specificity of 69%, 67%, and 69% to identify SR-LVS < 0.5 mV, respectively. Lower thresholds for the posterior wall (0.27 mV) and inferior wall (0.3 mV) result in higher spatial concordance to SR-LVS (4% and 7% increase). Concordance with SR-LVS was higher for induced AF compared to native AF (area under the curve[AUC]: 0.80 vs. 0.73). AF-LVS < 0.5 mV corresponds to SR-LVS < 0.97 mV (AUC: 0.73). CONCLUSION: Although the proposed region-specific voltage thresholds during AF improve the consistency of LVS identification as determined during SR, the concordance in LVS between SR and AF remains moderate, with larger LVS detection during AF. Voltage-based substrate ablation should preferentially be performed during SR to limit the amount of ablated atrial myocardium.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/cirugía
5.
Front Cardiovasc Med ; 10: 1110165, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37051067

RESUMEN

Introduction: Outcomes of catheter ablation for non-paroxysmal atrial fibrillation (AF) remain suboptimal. Non-invasive stratification of patients based on the presence of atrial cardiomyopathy (ACM) could allow to identify the best responders to pulmonary vein isolation (PVI). Methods: Observational multicentre retrospective study in patients undergoing cryoballoon-PVI for non-paroxysmal AF. The duration of amplified P-wave (APW) was measured from a digitally recorded 12-lead electrocardiogram during the procedure. If patients were in AF, direct-current cardioversion was performed to allow APW measurement in sinus rhythm. An APW cut-off of 150 ms was used to identify patients with significant ACM. We assessed freedom from arrhythmia recurrence at long-term follow-up in patients with APW ≥ 150 ms vs. APW < 150 ms. Results: We included 295 patients (mean age 62.3 ± 10.6), of whom 193 (65.4%) suffered from persistent AF and the remaining 102 (34.6%) from long-standing persistent AF. One-hundred-forty-two patients (50.2%) experienced arrhythmia recurrence during a mean follow-up of 793 ± 604 days. Patients with APW ≥ 150 ms had a significantly higher recurrence rate post ablation compared to those with APW < 150 ms (57.0% vs. 41.6%; log-rank p < 0.001). On a multivariable Cox-regression analysis, APW≥150 ms was the only independent predictor of arrhythmia recurrence post ablation (HR 2.03 CI95% 1.28-3.21; p = 0.002). Conclusion: APW duration predicts arrhythmia recurrence post cryoballoon-PVI in persistent and long-standing persistent AF. An APW cut-off of 150 ms allows to identify patients with significant ACM who have worse outcomes post PVI. Analysis of APW represents an easy, non-invasive and highly reproducible diagnostic tool which allows to identify patients who are the most likely to benefit from PVI-only approach.

6.
Front Cardiovasc Med ; 10: 1095931, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36910532

RESUMEN

Aim: This study sought to develop and validate diagnostic models to identify individuals with atrial fibrillation (AF) using amplified sinus-p-wave analysis. Methods: A total of 1,492 patients (491 healthy controls, 499 with paroxysmal AF and 502 with persistent AF) underwent digital 12-lead-ECG recording during sinus rhythm. The patient cohort was divided into training and validation set in a 3:2 ratio. P-wave indices (PWI) including duration of standard p-wave (standard PWD; scale at 10 mm/mV, sweep speed at 25 mm/s) and amplified sinus-p-wave (APWD, scale at 60-120 mm/mV, sweep speed at 100 mm/s) and advanced inter-atrial block (aIAB) along with other clinical parameters were used to develop diagnostic models using logistic regression. Each model was developed from the training set and further tested in both training and validation sets for its diagnostic performance in identifying individuals with AF. Results: Compared to standard PWD (Reference model), which achieved an AUC of 0.637 and 0.632, for training and validation set, respectively, APWD (Basic model) importantly improved the accuracy to identify individuals with AF (AUC = 0.86 and 0.866). The PWI-based model combining APWD, aIAB and body surface area (BSA) further improved the diagnostic performance for AF (AUC = 0.892 and 0.885). The integrated model, which further combined left atrial diameter (LAD) with parameters of the PWI-based model, achieved optimal diagnostic performance (AUC = 0.916 and 0.902). Conclusion: Analysis of amplified p-wave during sinus rhythm allows identification of individuals with atrial fibrillation.

7.
Eur Heart J Open ; 3(1): oeac085, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36654964

RESUMEN

Aims: With recurrence rates up to 50% after pulmonary vein isolation (PVI) in persistent atrial fibrillation (AF), predictive tools to improve patient selection are needed. Patient selection based on left atrial late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) has been proposed previously (UTAH-classification). However, this approach has not been widely established, in part owed to the lack of standardization of the LGE quantification method. We have recently established a standardized LGE-CMR method enabling reproducible LGE-quantification. Here, the ability of this method to predict outcome after PVI was evaluated. Methods and results: This dual-centre study (n = 219) consists of a prospective derivation cohort (n = 37, all persistent AF) and an external validation cohort (n = 182; 66 persistent, 116 paroxysmal AF). All patients received an LGE-CMR prior to first-time PVI-only ablation. LGE was quantified based on the signal-intensity-ratio relative to the blood pool, applying a uniform LGE-defining threshold of >1.2.  In patients with persistent AF in the derivation cohort, left atrial LGE-extent above a cut-off value of 12% was found to best predict relevant low-voltage substrate (≥2 cm two with <0.5 mV during sinus rhythm) and arrhythmia-free survival 12 months post-PVI. When applied to the external validation cohort, this cut-off value was also predictive of arrhythmia-free survival for both, the total cohort and the subgroup with persistent AF (LGE < 12%: 80% and 76%; LGE > 12%: 55% and 44%; P = 0.007 and P = 0.029, respectively). Conclusion: This dual-centre study established and validated a standardized, reproducible LGE-CMR method discriminating PVI responders from non-responders, which may improve choice of therapeutic approach or ablation strategy for patients with persistent AF.

8.
Europace ; 25(3): 1126-1134, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36610064

RESUMEN

AIMS: Transseptal puncture (TP) for left-sided catheter ablation procedures is routinely performed under fluoroscopic or echocardiographic guidance [transoesophageal echocardiography (TEE) or intracardiac echocardiography (ICE)], although three-dimensional (3D) mapping systems are readily available in most electrophysiology laboratories. Here, we sought to assess the feasibility and safety of a right atrial (RA) 3D map-guided TP. METHODS AND RESULTS: In 104 patients, 3D RA mapping was performed to identify the fossa ovalis (FO) using the protrusion technique. The radiofrequency transseptal needle was visualized and navigated to the desired potential FO-TP site. Thereafter, the interventionalist was unblinded to TEE and the potential FO-TP site was reassessed regarding its convenience and safety. After TP, the exact TP site was documented using a 17-segment-FO model. Reliable identification of the FO was feasible in 102 patients (98%). In these, 114 3D map-guided TP attempts were performed, of which 96 (84%) patients demonstrated a good position and 18 (16%) an adequate position after TEE unblinding. An out-of-FO or dangerous position did not occur. A successful 3D map-guided TP was performed in 110 attempts (97%). Four attempts (3%) with adequate positions were aborted in order to seek a more convenient TP site. The median time from RA mapping until the end of the TP process was 13 (12-17) min. No TP-related complications occurred. Ninety-eight TP sites (85.1%) were in the central portion or in the inner loop of the FO. CONCLUSION: A 3D map-guided TP is feasible and safe. It may assist to decrease radiation exposure and the need for TEE/ICE during left-sided catheter ablation procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Estudios de Factibilidad , Cateterismo Cardíaco/métodos , Atrios Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Punciones , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Resultado del Tratamiento
9.
J Cardiovasc Electrophysiol ; 34(1): 90-98, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36217994

RESUMEN

INTRODUCTION: Phrenic nerve (PN) injury is a rare but severe complication of radiofrequency (RF) pulmonary vein isolation (PVI). The objective of this study was to characterize the typical intracardiac course of the PN with a three-dimensional electroanatomic mapping system, to quantify the need for modification of the ablation trajectory to avoid delivering an ablation lesion on sites with PN capture, and to identify very circumscribed areas of common PNC on the routine ablation trajectory of a RF-PVI, allowing fast and effective PN screening for everyday usage. METHODS: We enrolled 137 consecutive patients (63 ± 9 years, 64% men) undergoing PVI. A detailed high output (20 mA) pace-mapping protocol was performed in the right (RA) and left atrium (LA) and adjacent vasculature. RESULTS: The right PN was most commonly captured in the superior vena cava at a lateral (50%) or posterolateral (23%) position before descending along the RA either straight (29%) or with a posterolateral bend (20%). In the LA, beginning deep within the right superior pulmonary vein (RSPV), the right PN is most frequently detectable anterolateral (31%), then descends to the lateral proximal RSPV (23%), and further towards the lateral antral region (15%) onto the medial LA wall (12%). To avoid delivering an ablation lesion on sites with PN capture, modification of ablation trajectory was necessary in 23% of cases, most commonly in the lateral RSPV antrum (81%). No PN injury occurred. CONCLUSION: PN mapping frequently reveals the close proximity of the PN to the ablation trajectory during PVI, particularly in the lateral RSPV antrum. Routine PN pacing should be considered during RF PVI procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Traumatismos de los Nervios Periféricos , Venas Pulmonares , Masculino , Humanos , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Nervio Frénico/lesiones , Venas Pulmonares/cirugía , Vena Cava Superior/cirugía , Atrios Cardíacos/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Traumatismos de los Nervios Periféricos/diagnóstico , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/prevención & control
10.
Europace ; 25(1): 211-222, 2023 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-35943361

RESUMEN

AIMS: The long-term success rate of ablation therapy is still sub-optimal in patients with persistent atrial fibrillation (AF), mostly due to arrhythmia recurrence originating from arrhythmogenic sites outside the pulmonary veins. Computational modelling provides a framework to integrate and augment clinical data, potentially enabling the patient-specific identification of AF mechanisms and of the optimal ablation sites. We developed a technology to tailor ablations in anatomical and functional digital atrial twins of patients with persistent AF aiming to identify the most successful ablation strategy. METHODS AND RESULTS: Twenty-nine patient-specific computational models integrating clinical information from tomographic imaging and electro-anatomical activation time and voltage maps were generated. Areas sustaining AF were identified by a personalized induction protocol at multiple locations. State-of-the-art anatomical and substrate ablation strategies were compared with our proposed Personalized Ablation Lines (PersonAL) plan, which consists of iteratively targeting emergent high dominant frequency (HDF) regions, to identify the optimal ablation strategy. Localized ablations were connected to the closest non-conductive barrier to prevent recurrence of AF or atrial tachycardia. The first application of the HDF strategy had a success of >98% and isolated only 5-6% of the left atrial myocardium. In contrast, conventional ablation strategies targeting anatomical or structural substrate resulted in isolation of up to 20% of left atrial myocardium. After a second iteration of the HDF strategy, no further arrhythmia episode could be induced in any of the patient-specific models. CONCLUSION: The novel PersonAL in silico technology allows to unveil all AF-perpetuating areas and personalize ablation by leveraging atrial digital twins.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Taquicardia Supraventricular , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Atrios Cardíacos/cirugía , Simulación por Computador , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
11.
Europace ; 25(1): 65-73, 2023 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-35852306

RESUMEN

AIMS: The cornerstone of pulmonary vein (PV) isolation (PVI) is a wide-area circumferential ablation (WACA) resulting in an antral PVI area. Pulsed-field ablation (PFA) is a new nonthermal 'single-shot' PVI technique resulting in well-characterized posterior isolation areas. However, information on circumferential PVI area is lacking. Thus, we sought to characterize the circumferential antral PVI areas after PFA-PVI. METHODS AND RESULTS: Atrial fibrillation (AF) patients underwent fluoroscopy-guided PVI with a pentaspline PFA catheter. Ultra-high-density voltage maps using a 20-polar circular mapping catheter were created before and immediately after PVI to identify and quantify (i) insufficient isolation areas per antral PV segment (10-segment model) and (ii) enlarged left atrial (LA) isolation areas (beyond the antral PV segments) per LA region (8-region model). The PFA-PVI with pre- (5469 ± 1822 points) and post-mapping (6809 ± 2769 points) was performed in 40 consecutive patients [age 62 ± 6 years, 25/40 (62.5%) paroxysmal AF]. Insufficient isolation areas were located most frequently in the anterior antral PV segments of the left PVs (62.5-77.5% of patients) with the largest extent (median ≥0.4 cm2) located in the same segments (segments 2/5/8). Enlarged LA isolation areas were located most frequently and most extensively on the posterior wall and roof region (89.5-100% of patients; median 1.1-2.7 cm2 per region). CONCLUSION: Fluoroscopy-guided PFA-PVI frequently results in insufficient isolation areas in the left anterior antral PV segments and enlarged LA isolation areas on the posterior wall/roof, which both may be extensive. To optimize the procedure, full integration of PFA catheter visualization into three-dimensional-mapping systems is needed.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Persona de Mediana Edad , Anciano , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Atrios Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Catéteres , Resultado del Tratamiento
12.
Front Cardiovasc Med ; 9: 1000027, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36330001

RESUMEN

Background: Low-voltage-substrate (LVS)-guided ablation for persistent atrial fibrillation (AF) has been described either in sinus rhythm (SR) or AF. Prolonged fractionated potentials (PFPs) may represent arrhythmogenic slow conduction substrate and potentially co-localize with LVS. We assess the spatial correlation of PFP identified in AF (PFP-AF) to those mapped in SR (PFP-SR). We further report the relationship between LVS and PFPs when mapped in AF or SR. Materials and methods: Thirty-eight patients with ablation naïve persistent AF underwent left atrial (LA) high-density mapping in AF and SR prior to catheter ablation. Areas presenting PFP-AF and PFP-SR were annotated during mapping on the LA geometry. Low-voltage areas (LVA) were quantified using a bipolar threshold of 0.5 mV during both AF and SR mapping. Concordance of fractionated potentials (CFP) (defined as the presence of PFPs in both rhythms within a radius of 6 mm) was quantified. Spatial distribution and correlation of PFP and CFP with LVA were assessed. The predictors for CFP were determined. Results: PFPs displayed low voltages both during AF (median 0.30 mV (Q1-Q3: 0.20-0.50 mV) and SR (median 0.35 mV (Q1-Q3: 0.20-0.56 mV). The duration of PFP-SR was measured at 61 ms (Q1-Q3: 51-76 ms). During SR, most PFP-SRs (89.4 and 97.2%) were located within LVA (<0.5 mV and <1.0 mV, respectively). Areas presenting PFP occurred more frequently in AF than in SR (median: 9.5 vs. 8.0, p = 0.005). Both PFP-AF and PFP-SR were predominantly located at anterior LA (>40%), followed by posterior LA (>20%) and septal LA (>15%). The extent of LVA < 0.5 mV was more extensive in AF (median: 25.2% of LA surface, Q1-Q3:16.6-50.5%) than in SR (median: 12.3%, Q1-Q3: 4.7-29.4%, p = 0.001). CFP in both rhythms occurred in 80% of PFP-SR and 59% of PFP-AF (p = 0.008). Notably, CFP was positively correlated to the extent of LVA in SR (p = 0.004), but not with LVA in AF (p = 0.226). Additionally, the extent of LVA < 0.5 mV in SR was the only significant predictor for CFP, with an optimal threshold of 16% predicting high (>80%) fractionation concordance in AF and SR. Conclusion: Substrate mapping in SR vs. AF reveals smaller areas of low voltage and fewer sites with PFP. PFP-SR are located within low-voltage areas in SR. There is a high degree of spatial agreement (80%) between PFP-AF and PFP-SR in patients with moderate LVA in SR (>16% of LA surface). These findings should be considered when substrate-based ablation strategies are applied in patients with the left atrial low-voltage substrate with recurrent persistent AF.

13.
J Clin Med ; 11(19)2022 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-36233446

RESUMEN

BACKGROUND: Permanent pacemaker implantation (PPI) after transcatheter valve implantation (TAVI) is a common complication. Pre-existing right bundle branch block (RBBB) is a strong risk factor for PPI after TAVI. However, a patient-specific approach for risk stratification in this subgroup has not yet been established. METHODS: We investigated TAVI patients with pre-existing RBBB to stratify risk factors for PPI and 1-year-mortality by detailed analysis of ECG data, RBBB morphology and degree of calcification in the implantation area assessed by computed tomography angiography. RESULTS: Between 2010 and 2018, 2129 patients underwent TAVI at our institution. Among these, 98 pacemaker-naïve patients with pre-existing RBBB underwent a TAVI procedure. PPI, because of relevant conduction disturbances (CD), was necessary in 43 (43.9%) patients. PPI was more frequently indicated in women vs. men (62.1% vs. 32.8%, p = 0.004) and in men treated with a self-expandable vs. a balloon-expandable valve (58.3% vs. 26.5%, p = 0.035). ECG data (heart rhythm, PQ, QRS, QT) and RBBB morphology had no influence on PPI rate, whereas risk for PPI increased with the degree of calcification in the left septal His-/left bundle branch-area to a 9.375-fold odds for the 3rd tertile of calcification (1.639-53.621; p = 0.012). Overall, 1-year-mortality was comparable among patients with or without PPI (14.0% vs. 16.4%; p = 0.697). CONCLUSIONS: Patients with RBBB undergoing TAVI have a high risk of PPI. Among this subgroup, female patients, male patients treated with self-expandable valve types, patients with high load/degree of non-coronary LVOT calcification and patients with atrial fibrillation need enhanced surveillance for CD after procedure.

14.
J Clin Med ; 11(5)2022 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-35268425

RESUMEN

Objective: Atrial cardiomyopathy (ACM) is associated with development of AF, left atrial (LA) thrombogenesis, and stroke. Diagnosis of ACM is feasible using both echocardiographic LA strain imaging and measurement of the amplified p-wave duration (APWD) in digital 12-lead-ECG. We sought to determine the thresholds of LA global longitudinal strain (LA-GLS) and APWD that identify patients with AF at risk for LA appendage (LAA) thrombogenesis. Methods: One hundred and twenty-eight patients with a history of AF were included. Left atrial appendage maximal flow velocity (LAA-Vel, in TEE), LA-GLS (TTE), and APWD (digital 12-lead-ECG) were measured in all patients. ROC analysis was performed for each method to determine the thresholds for LA-GLS and the APWD, enabling diagnosis of patients with LAA-thrombus. Results: Significant differences in LA-GLS were found during both rhythms (SR and AF) between the thrombus group and control group: LA-GLS in SR: 14.3 ± 7.4% vs. 24.6 ± 9.0%, p < 0.001 and in AF: 11.4 ± 4.2% vs. 16.1 ± 5.0%, p = 0.045. ROC analysis revealed a threshold of 17.45% for the entire cohort (AUC 0.82, sensitivity: 84.6%, specificity: 63.6%, Negative Predictive Value (NPV): 94.3%) with additional rhythm-specific thresholds: 19.1% in SR and 13.9% in AF, and a threshold of 165 ms for APWD (AUC 0.90, sensitivity: 88.5%, specificity: 75.5%, NPV: 96.2%) as optimal discriminators of LAA-thrombus. Moreover, both LA-GLS and APWD correlated well with the established contractile LA-parameter LAA-Vel in TEE (r = 0.39, p < 0.001 and r = −0.39, p < 0.001, respectively). Conclusion: LA-GLS and APWD are valuable diagnostic predictors of left atrial thrombogenesis in patients with AF.

15.
Europace ; 24(7): 1102-1111, 2022 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-35298612

RESUMEN

AIMS: Atrial cardiomyopathy (ACM) is associated with increased arrhythmia recurrence rates after pulmonary vein isolation (PVI). We compare the most common left atrial (LA) late gadolinium enhancement magnetic resonance imaging (LGE-MRI)-methods [Utah-method and image intensity ratio (IIR)-methods] and endocardial voltage mapping for ACM-detection and outcome prediction after PVI for atrial fibrillation (AF). METHODS AND RESULTS: In this prospective observational study, 37 ablation-naive patients (66 ± 9 years, 84% male) with persistent AF underwent LA-LGE-MRI and high-definition voltage and activation mapping (2129 ± 484 sites) in sinus rhythm prior to PVI. The MRI-post-processing-analyses were performed by two independent expert laboratories. Arrhythmia recurrence was recorded within 12 months following PVI. The global ACM-extent was highly variable: median LA low-voltage substrate (LA-LVS) was 12.9% at <1.0 mV and 2.7% at <0.5 mV; median LA-LGE-extent using the Utah-method was 18.3% and 0.03-93.1% using the IIR-methods. The LA activation time was significantly correlated with LA-LVS (r = 0.76 at <0.5 mV and r = 0.82 at <1.0 mV, both P < 0.0001), but not with LA-LGE-extent. The highest regional matching between LA-LVS <0.5 mV and LA-LGE was found for the anterior wall in 57% of patients using the Utah-method and in 59% using IIR 1.20. The corresponding values for the posterior wall were 19% and 38%, respectively. Arrhythmia recurrence occurred in 15(41%) patients. Freedom from arrhythmia was significantly lower in those with LA-LVS ≥2 cm2 at 0.5 mV but not in those with LGE ≥20% (Utah-stages III and IV): 43% vs. 81%, P = 0.009 and 50% vs. 67%, P = 0.338, respectively. CONCLUSION: Comparison of the most common LA-LGE-MRI methods and endocardial voltage mapping revealed large discrepancies in global and regional ACM-extent.


Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Ablación por Catéter , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Medios de Contraste , Femenino , Gadolinio , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/patología , Atrios Cardíacos/cirugía , Humanos , Imagen por Resonancia Magnética/métodos , Masculino
16.
Catheter Cardiovasc Interv ; 99(5): 1582-1589, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35043554

RESUMEN

OBJECTIVES: We sought to assess the impact of echocardiographic and hemodynamic grading of paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI) on the prediction of 5-year mortality. PVL after TAVI is known to influence outcome after TAVI. Yet, present available data of long-term outcomes and especially the comparison of different modalities for measurement of PVL is little. METHODS: We performed a retrospective single-center cohort study and compared the prognostic value of echocardiographic PVL grading as well as the aortic regurgitation index (ARI) pre- and post-TAVI. Univariable and multivariable Cox proportional regression analysis generated hazard ratios for mortality. RESULTS: A total of 464 patients underwent TAVI at our center between August 2012 and Decemebr 2014, with self-expandable CoreValve (11%) or balloon-expandable Sapien XT (47.4%) and Sapien 3 (41.6) valves. Overall 5-year mortality was 52.4% (243/464). Echocardiographic classes of PVL at discharge showed a significant (p = 0.002) association with 5-year mortality, mild PVL remained as an independent predictor for 5-year mortality in multivariable analysis (hazard ratio: 1.642 [95% confidence interval: 1.235-2.182]; p = 0.001). Grades of PVL as assessed during the procedure by ARI (below the previously defined cut-off of 25) did not show a significant association with 5-year mortality (p = 0.417 and p = 0.995, respectively). CONCLUSIONS: Even mild PVL assessed by echocardiography was an independent predictor for 5-year survival, whereas hemodynamic measurements did not help to identify PVLs that are relevant to 5-year survival.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios de Cohortes , Ecocardiografía , Hemodinámica , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
17.
Sci Rep ; 12(1): 576, 2022 01 12.
Artículo en Inglés | MEDLINE | ID: mdl-35022443

RESUMEN

Thromboembolism and stroke are dreaded complications in atrial fibrillation (AF). Established risk stratification models identify susceptible patients, but their discriminative properties are poor. Atrial cardiomyopathy (ACM) is associated to thromboembolism and stroke in smaller studies, but the modalities used for ACM-diagnosis (MRI and endocardial mapping) are unsuitable for widespread population screening. We aimed to investigate an ECG-based diagnosis of ACM using amplified p-wave analysis (APWA) for stratification of thromboembolic risk and cardiovascular outcome. In this case-control study, ACM-staging was performed using APWA on digital 12-lead sinus rhythm-ECGs in patients with LAA-thrombus and a propensity-score-matched control-cohort. Left atrial contractile function and thrombi were evaluated by transesophageal echocardiography (TEE). Outcome for MACCE including death was assessed using official registries and structured phone interviews. Left-atrial appendage [LAA]-thrombi and appropriate sinus rhythm-ECGs for ACM-staging were found in 109 of 4086 patients that were matched 1:1 to control patients without thrombus (218 patients in total). Both cohorts were comparable regarding cardiovascular risk factors, anticoagulants and CHA2DS2-VASC-score. ACM-stages 1 to 3 (equivalent to no, moderate and extensive ACM) were found in 63 (57.8%), 36 (33.0%) and 10 (9.2%) of patients without and 3 (2.8%), 23 (21.1%) and 83 (76.1%) of patients with LAA-thrombi. Atrial contractile function decreased from ACM-stages 1 to 3 (LAA-flow velocities 38 ± 16 cm/s, 31 ± 15 cm/s and 21 ± 12 cm/s; p < 0.0001), while the likelihood for LAA-thrombus increased (2.8%, 21.1% and 76.1%, p < 0.001). Multivariable analysis confirmed an independent odds ratio for LAA-thrombus of 24.6 (p < 0.001) per ACM-stage. Two-year survival free of stroke/TIA, hospitalization for heart failure, myocardial infarction or all-cause death was strongly reduced in ACM-stage 3 (53.8%) compared to no or moderate ACM (82.8% and 84.7%, respectively; p < 0.0001). Electrocardiographic diagnosis of ACM identifies patients with atrial contractile dysfunction and atrial thrombi at risk for adverse cardiovascular outcomes and death.


Asunto(s)
Fibrilación Atrial/complicaciones , Cardiomiopatías/diagnóstico , Electrocardiografía/métodos , Trombosis/diagnóstico , Anciano , Anciano de 80 o más Años , Apéndice Atrial , Función del Atrio Izquierdo , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Trombosis/complicaciones
18.
Clin Res Cardiol ; 111(9): 1018-1027, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34854991

RESUMEN

AIMS: Despite advances in interventional treatment strategies, atrial fibrillation (AF) remains associated with significant morbidity and mortality. Fibrotic atrial myopathy (FAM) is a main factor for adverse outcomes of AF-ablation, but complex to diagnose using current methods. We aimed to derive a scoring system based entirely on easily available clinical parameters to predict FAM and ablation-success in everyday care. METHODS: In this multicenter, prospective study, a new risk stratification model termed AF-SCORE was derived in 220 patients undergoing high-density left-atrial(LA) voltage-mapping to quantify FAM. AF-SCORE was validated for FAM in an external mapping-validation cohort (n = 220) and for success following pulmonary vein isolation (PVI)-only (without adjunctive left- or right atrial ablations) in an external outcome-validation cohort (n = 518). RESULTS: FAM was rare in patients < 60 years (5.4%), but increased with ageing and affected 40.4% (59/146) of patients ≥ 60 years. Sex and AF-phenotype had additional predictive value in older patients and remained associated with FAM in multivariate models (odds ratio [OR] 6.194, p < 0.0001 for ≥ 60 years; OR 2.863, p < 0.0001 for female sex; OR 41.309, p < 0.0001 for AF-persistency). Additional clinical or diagnostic variables did not improve the model. AF-SCORE (+ 1 point for age ≥ 60 years and additional points for female sex [+ 1] and AF-persistency [+ 2]) showed good discrimination to detect FAM (c-statistic 0.792) and predicted arrhythmia-freedom following PVI (74.3%, 54.7% and 45.5% for AF-SCORE ≤ 2, 3 and 4, respectively, and hazard ratio [HR] 1.994 for AF-SCORE = 3 and HR 2.866 for AF-SCORE = 4, p < 0.001). CONCLUSIONS: Age, sex and AF-phenotype are the main determinants for the development of FAM. A low AF-SCORE ≤ 2 is found in paroxysmal AF-patients of any age and younger patients with persistent AF irrespective of sex, and associated with favorable outcomes of PVI-only. Freedom from arrhythmia remains unsatisfactory with AF-SCORE ≥ 3 as found in older patients, particularly females, with persistent AF, and future studies investigating adjunctive atrial ablations to PVI-only should focus on these groups of patients.


Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Cardiomiopatías/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Fibrosis , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
19.
Front Cardiovasc Med ; 9: 1101152, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36712269

RESUMEN

Background: Progressive atrial fibrotic remodeling has been reported to be associated with atrial cardiomyopathy (ACM) and the transition from paroxysmal to persistent atrial fibrillation (AF). We sought to identify the anatomical/structural and electrophysiological factors involved in atrial remodeling that promote AF persistency. Methods: Consecutive patients with paroxysmal (n = 134) or persistent (n = 136) AF who presented for their first AF ablation procedure were included. Patients underwent left atrial (LA) high-definition mapping (1,835 ± 421 sites/map) during sinus rhythm (SR) and were randomized to training and validation sets for model development and evaluation. A total of 62 parameters from both electro-anatomical mapping and non-invasive baseline data were extracted encompassing four main categories: (1) LA size, (2) extent of low-voltage-substrate (LVS), (3) LA voltages and (4) bi-atrial conduction time as identified by the duration of amplified P-wave (APWD) in a digital 12-lead-ECG. Least absolute shrinkage and selection operator (LASSO) and logistic regression were performed to identify the factors that are most relevant to AF persistency in each category alone and all categories combined. The performance of the developed models for diagnosis of AF persistency was validated regarding discrimination, calibration and clinical usefulness. In addition, HATCH score and C2HEST score were also evaluated for their performance in identification of AF persistency. Results: In training and validation sets, APWD (threshold 151 ms), LA volume (LAV, threshold 94 mL), bipolar LVS area < 1.0 mV (threshold 4.55 cm2) and LA global mean voltage (GMV, threshold 1.66 mV) were identified as best determinants for AF persistency in the respective category. Moreover, APWD (AUC 0.851 and 0.801) and LA volume (AUC 0.788 and 0.741) achieved better discrimination between AF types than LVS extent (AUC 0.783 and 0.682) and GMV (AUC 0.751 and 0.707). The integrated model (combining APWD and LAV) yielded the best discrimination performance between AF types (AUC 0.876 in training set and 0.830 in validation set). In contrast, HATCH score and C2HEST score only achieved AUC < 0.60 in identifying individuals with persistent AF in current study. Conclusion: Among 62 electro-anatomical parameters, we identified APWD, LA volume, LVS extent, and mean LA voltage as the four determinant electrophysiological and structural factors that are most relevant for AF persistency. Notably, the combination of APWD with LA volume enabled discrimination between paroxysmal and persistent AF with high accuracy, emphasizing their importance as underlying substrate of persistent AF.

20.
Heart Rhythm ; 18(12): 2040-2047, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34400310

RESUMEN

BACKGROUND: Conduction disturbances after transcatheter aortic valve implantation (TAVI) are common, heterogeneous, and frequently result in permanent pacemaker implantation (PPI). Pacemaker therapy with a high rate of right ventricular pacing is associated with heart failure, hospitalizations, and reduced quality of life. OBJECTIVE: The purpose of this study was to compare medium-term outcomes between PPI implantation strategies, as choosing the right indication for PPI is still an area of uncertainty and information on outcomes of PPI regimens beyond 1 year is rare. METHODS: We compared outcomes after 3 years between a restrictive PPI strategy, in which the lowest threshold for PPI was left bundle branch block (LBBB) (QRS >120 ms) with the presence of new atrioventricular block (PQ >200 ms), and a liberal PPI regimen, in which PPI already was performed in patients with new-onset LBBB. RESULTS: Between January 2014 and December 2016, TAVI was performed in 884 patients at our center. Of these, 383 consecutive, pacemaker-naive patients underwent TAVI with the liberal PPI strategy and subsequently 384 with the restrictive strategy. The restrictive strategy significantly reduced the percentage of patients undergoing PPI before discharge (17.2% vs 38.1%; P <.001). The incidence of the primary endpoint (all-cause-mortality and hospitalization for heart failure) after 3 years was similar in both groups (30.7% vs 35.2%; P = .242), as was all-cause-mortality (26.6% vs 29.2%; P = .718). Overall, patients who required PPI post-TAVI had significantly more hospitalizations due to heart failure (14.8% vs 7.8%; P = .004). CONCLUSION: A restrictive PPI strategy after TAVI reduces PPI significantly and is safe in medium-term follow-up over 3 years.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Arritmias Cardíacas/etiología , Marcapaso Artificial , Calidad de Vida , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Humanos , Incidencia , Masculino , Estudios Retrospectivos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...